Klover Smart 80 BT Installation in Boroughbridge YO519BZ

Existing central heating system upgrade with pellet boiler to heat the house and produce hot water. Backup heater is gas combi boiler.

Description of work

We installed a Klover Smart 80 pellet boiler as an addition to the existing combi boiler heating system. It is very similar to Klover Smart 120 with similar heating capacity, but doesn’t have an oven.
Afterwards we have installed a solar thermal system to produce hot water from spring to autumn.

Features

  • The pellet boiler has priority. The gas boiler kicks in only the pellet boiler is not able to produce heat from any reason
  • The control is based on Honeywell Evohome controller with 12 zones with radiator actuators and another zone for underfloor heating. Unfortuntely Evohome is not suitable to fully control a complex system like this, so additional heating controller was required.
  • It is possible to start the cooker independently from heat demand for cooking. If the boiler gets too hot due to long period of cooking without heat demand the central heating starts to keep the temperature within limits.

The system is fully MCS compilant.

Location of stove

The stove has been located in the kitchen on the main place.
Klover cooker boiler stove in the kitchen
Klover cooker boiler stove in the kitchen

Hot water cylinder
Hot water cylinder

Evohome zones
Evohome zones

Hydraulic schematics

Hydraulic Schematics
Hydraulic Schematics

Heating distribution board
Heating distribution board

Heating controller and the Evohome relays below
Heating controller and the Evohome relays below

Solar thermal panels on the roof
Solar thermal panels on the roof

HETAS
MCS certificated
NAPIT
RECC
Home Improvement Protection
Skip to toolbar